David Clark 9800 Series Instrukcja Instalacji Strona 27

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 43
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 26
1
9532P-62 (03-11)
23
of 32
q C
onnect the cable to the jack on the Master Station labeled “Power Cable”, see Figures 1&4.
To connect the cable to the Master Station, align keyways and push. Then firmly turn collar
clockwise until it locks into place. Pull back gently on the cable to ensure connector is properly
locked.
Before continuing, ensure that power is shut off to the point where you are
going to connect the power cable!
q Using the wire cutters and wire strippers, prepare the end of the cable as necessary for your
installation (Figure 15).
q If using the David Clark 2-Amp Fuse Kit, please see Appendix B for assembly instructions.
q Connect the cable to the power source
o Connect the RED to the positive (+) terminal.
o Connect the BLACK and SHIELD to the negative (-) terminal.
q Do not turn on power at this time, wait until Section 11. Testing & Troubleshooting.
To 2 amp
c
ircuit
breaker/fuse
RED
BL
ACK/SHIELD
F
igure 15: C98-20PW Power Cable